Back

Novell Tested Software

Partner Hardware Type Hardware Model Data Rate Partner Model Number Equivalent Emulex Model Number Physical Connection Cable
Novell Software SUSE Linux Enterprise 10Gb/s OCe10102-IX   SFP+
  • 10GBase-CR
  • Transceiver not included
DAC/TwinAx
Novell Software SUSE Linux Enterprise 10Gb/s OCe10102-NX   SFP+
  • 10GBase-CR
  • Transceiver not included
DAC/TwinAx
Novell Software SUSE Linux Enterprise 10Gb/s LP21000   SFP+
  • 10GBase-SR
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 10Gb/s LP21002   SFP+
  • 10GBase-SR
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 10Gb/s OCe10102-IM   SFP+
  • 10GBase-SR
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 10Gb/s OCe10102-NM   SFP+
  • 10GBase-SR
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 8Gb/s LPe1205-CIOv   KR
  • Mezzanine
  • Transceiver not included
 
Novell Software SUSE Linux Enterprise 8Gb/s LPe1205-FJ   KR
  • Mezzanine
  • Transceiver not included
 
Novell Software SUSE Linux Enterprise 8Gb/s LPe1205-HP   KR
  • Mezzanine
  • Transceiver not included
 
Novell Software SUSE Linux Enterprise 8Gb/s LPe1205-M   KR
  • Mezzanine
  • Transceiver not included
 
Novell Software SUSE Linux Enterprise 8Gb/s LPe12000   SFP+
  • Short Range - LC
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 8Gb/s LPe12002   SFP+
  • Short Range - LC
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 8Gb/s LPe1250   SFP+
  • Short Range - LC
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 4Gb/s LP1105-BC   KR
  • Mezzanine
  • Transceiver not included
 
Novell Software SUSE Linux Enterprise 4Gb/s LP1105-BCv   KR
  • Mezzanine
  • Transceiver not included
 
Novell Software SUSE Linux Enterprise 4Gb/s LP1105-BU   KR
  • Mezzanine
  • Transceiver not included
 
Novell Software SUSE Linux Enterprise 4Gb/s LPe1105-HP   KR
  • Mezzanine
  • Transceiver not included
 
Novell Software SUSE Linux Enterprise 4Gb/s LPe1105-M4   KR
  • Mezzanine
  • Transceiver not included
 
Novell Software SUSE Linux Enterprise 4Gb/s BX600-FC42E LPe1105-HP KR
  • Mezzanine
  • Transceiver not included
 
Novell Software SUSE Linux Enterprise 4Gb/s LPe11020-S   SFP
  • Short Range - LC
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 4Gb/s LP11000   SFP
  • Short Range - LC
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 4Gb/s LP11002   SFP
  • Short Range - LC
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 4Gb/s LP1150   SFP
  • Short Range - LC
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 4Gb/s LPe11000   SFP
  • Short Range - LC
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 4Gb/s LPe11002   SFP
  • Short Range - LC
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 4Gb/s LPe11004   SFP
  • Short Range - LC
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 4Gb/s LPe1150   SFP
  • Short Range - LC
  • Transceiver included
Multi-Mode Fibre Optic
Novell Software SUSE Linux Enterprise 4Gb/s LPem11002-S   SFP
  • Short Range - LC
  • Transceiver included
Multi-Mode Fibre Optic

Multi-Mode Fibre Optic

Emulex adapters support Multi Mode Fibre Optic Cables (MMF) with LC type connector. "LC" refers to the actual connector on the end of the cable, and it stands for "Lucent Connector". There are several kinds of MMF cables that can be purchased, the difference between one type of MMF cable and another is in the size of the core of the cable, which then determines how far apart the HBA can be from a target – also called the link length. Link length is also contingent on the bandwidth designation of the cable, OM1, OM2, OM3, OM4.

Fibre Optic Cable Characteristics

  Mode Core Diameter Wavelength Modal Bandwidth Cable Jacket Color
OM1 Multi-Mode 62.5 µm 850nm/1300nm 200MHz Orange
OM2 Multi-Mode 50 µm 850nm/1300nm 500MHz Orange
OM3 Multi-Mode 50 µm 850nm/1300nm 2000MHz Aqua
OM4 Multi-Mode 50 µm 850nm/1300nm 4700MHz Aqua

SFP

SFP stands for Small Form Pluggable – the first generation of the SFP interconnect system, with a maximum data rate of 4.25Gb/s. Emulex Fibre Channel HBAs up to 4Gb/s, are shipped with one, two, or four SFP Optical Transceivers installed/soldered to the board.

Multi-Mode Fibre Optic

Emulex adapters support 10GBASE-SR "Short Range" short wave lasers, Multi Mode Fibre Optic Cables (MMF) with LC type connector, at lengths up to 100 meters. "LC" refers to the actual connector on the end of the cable, and it stands for "Lucent Connector". There are several kinds of MMF cables that can be purchased, the differences between MMF cables is in the size of the core of the cable, which then determines how far apart the CNA can be from a target – also called the link length. Link length is also contingent on the bandwidth designation of the cable, OM1, OM2, OM3, OM4.

Fibre Optic Cable Characteristics

  Mode Core Diameter Wavelength Modal Bandwidth Cable Jacket Color
OM1 Multi-Mode 62.5 µm 850nm/1300nm 200MHz Orange
OM2 Multi-Mode 50 µm 850nm/1300nm 500MHz Orange
OM3 Multi-Mode 50 µm 850nm/1300nm 2000MHz Aqua
OM4 Multi-Mode 50 µm 850nm/1300nm 4700MHz Aqua

SFP+

SFP+ stands for Small Form Pluggable Plus – the second generation of the SFP interconnect system, supporting data rates up to 10Gb/s. SFP+ modules can be plugged into an SFP+ cage that is installed on the board, which allows you to swap out an optical module in the event of a failure. Optical versions of OneConnect adapters (10GBASE-SR) ship with two SFP Optical Transceivers installed in the SFP+ cages on the board. Copper versions of OneConnect adapters (10GBASE-CR) can be connected with a Direct Attached Copper (DAC or TwinAx) cable.

SFP+

SFP+ stands for Small Form Pluggable Plus – the second generation of the SFP interconnect system, supporting data rates up to 10Gb/s. SFP+ modules can be plugged into an SFP+ cage that is installed on the board, which allows you to swap out an optical module in the event of a failure. If you order an 8Gb/s Emulex Fibre Channel HBA, it is shipped with one, two, or four SFP+ Optical Transceivers installed in the SFP+ cages on the board.

DAC/TwinAx

Emulex adapters support both Active and Passive types of Direct Attached Copper (DAC) devices. Refer to the specification for the switch that you will be connecting to when procuring DAC cables. These cables have a special type of transceiver soldered directly onto the cable. The idea is to convert the optical 10GBASE-SR laser signal into a signal that can be carried over short distances (up to 10 meters / about 30 feet) within a data center rack over the attached copper wires. This is also referred to as 10 GBASE-CR “Copper Reach”.

Back