STANDARDS
- Fibre Channel Protocols:
- FC-AL, FC-AL2, FC-PH, FC-PH2, FC-PI
- Interoperability:
- Connects to any FC-AL compliant device
- Compatible with the InSpeed API
- Compatible with InSpeed Embedded
- Storage Switches and previous generation InSpeed SOCs
ARCHITECTURE
- Fibre Channel Ports:
- 22
- Interfaces:
- Parallel bus microprocessor interface
- I2C interface for access to internal registers
- LED interface
- Testability interface
- Scalability:
- Up to 8 InSpeed SOCs
- Trunking:
- Automatic trunking fully multiplies throughput and bandwidth with failover pathing
- Zoning:
- Port- or ALPA-based overlapping and port-based non-overlapping
- Stability:
- Stealth Intelligent Change Manager automatically eliminates state and configuration change notification disruptions–zone and port-based management
- Integration:
- Integrated Fibre Channel Controller for in–band monitoring and control, including SES
- Switch-on-a-chip (SOC) with integrated support chips
- Embedded SERDES on each port
- Selectable termination/swing
- Equalization per port serial EEPROM restores system configuration on power-up - configured in standalone operation eliminates external microprocessor requirement
- Reference clock:
- 106.25 MHz LVTTL
PERFORMANCE
- Port Speed:
- 4, 2 or 1Gb/s bi-directional (800MBps per port, full duplex)
- Latency:
- Less than 1μSec with no contention, cut-through routing at 4Gb/s
- Performance:
- Full wire-speed switching
- Aggregate Bandwidth:
- 176Gb/s
- Switch Core:
- 23x23 non-blocking Crossbar switch core dynamically delivers multiple concurrent port-to-port connections
- Retiming:
- Architecture ensures jitter compliance and cleanest signals
- Fairness & Prioritization:
- Ensures all devices have guaranteed access to all other devices, or explicitly have prioritized access
PHYSICAL ATTRIBUTES
- Package:
- 35mm x 35mm footprint, 772-pin BGA
- Power & Nominal Dissipation:
- 3.3V / 2.5V / 1.2V; 6W
DIAGNOSTICS
- Continuous Diagnostic Operations:
- Power on self–test
- Port test before insertion
- Traffic & utilization monitoring
- Continuous link health monitoring
- Clock delta monitoring
- Pinpoint detection of drive problems
- Trend monitoring of device behavior
- Preventative action before failure
- Automatic bypass for rogue and unused ports
- Diagnostic Troubleshooting Tools:
- CRC error monitoring & counting
- Ordered set detectors
- Counters on every port
- Ordered set capture
- Ordered set transmit
- Port snoop
- Internal and external loopback



Twitter